Cannon 10850G Cooktop User Manual


 
TECHNICAL DATA
DIMENSIONS
Height 900 - 915mm
Width 1000mm
Depth 600mm (excluding door handles)
GENERAL
Gas connection Rp
1
/
2
(
1
/
2
” BSP female)
Pressure test point Hotplate burner injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection 230/240V a.c. 50Hz.
Total electrical heat input 7.2 kW
INSTALLATION INSTRUCTIONS
HEAT INPUT
HEAT
INPUT
BURNER
INJECTOR
HEAT
INPUT
GAS RATE
INJECTOR
Cat II
2H3+
G20 at 20 mbar
Cat II
2H3+
G30 at 28 - 30 mbar
G31 at 37 mbar
240V a.c.
2.66 kW
TWIN GRILL
2.50 kW
L/H OVEN
2.00 kW
R/H OVEN
0.22 kW
WARMING
DRAWER
2.0 kW
1.80 kW
HOTPLATE
Front Left
102
3.0 kW
HOTPLATE
Rear Left
128
HOTPLATE
Wok Outer
Centre Front
2 x 114
5.10 kW
2.80 kW
4.75 kW
HOTPLATE
Wok Inner
Centre Front
70
65
82
2 x 70
44
130g/hr
205g/hr
2.0 kW
1.8 kW
HOTPLATE
Front Right
102
2.0 kW
HOTPLATE
Rear Right
102
1.8 kW
65
65
130g/hr
1.02 kW
1.00 kW
HOTPLATE
Auxiliary
Centre Rear
72
50
75g/hr
130g/hr
345g/hr
26