Cannon C60GCIS Electric Pressure Cooker User Manual


 
32
INSTALLATION INSTRUCTIONS
STABILITY CHAIN
A hole in the gas inlet valve bracket can be used to engage a stability chain.
CONNECTING TO GAS SUPPLY
300
670
Connection to the cooker should be made with an approved appliance flexi ble connection to BS 669. A length of
0.9 to 1.25m is recommended. The length of hose chosen should be such that when the cooker is in situ, the
hose
does not touch the floor.
Those cookers converted to use on LPG should be connected with a hose suitable for LPG and capable of
withstanding a pressure of 50 mbar.
An adaptor backplate should be fitted within the shaded area shown, to
allow the cooker to be pushed fully to
the wall and to ensure that the flexible hose is only likely to come into contact with areas at the rear of the
cooker that do not exceed a temperature rise
of 70°C.