Capital Cooking PSCT36 Cooktop User Manual


 
12
do it yourself maintenance
WARNING!
POWER FAILURE
In the event of a power failure,
only the standard burners and
grill can be lit manually. It is
necessary to light each standard
burner individually.
If the cooktop is being used when
the power failure occurs, turn all
of the burner control knobs to the
OFF position.
Holding a match at the ports, then
by turning the control knob to the
HI position, can light the standard
burners and grill.
Wait until the flame is burning all
the way around the burner cap
before adjusting the flame to the
desired height.
INTERMITTENT OR CONSTANT
IGNITER SPARKING
Intermittent or constant sparking of the sealed
gas surface burners can result from a number
of preventable conditions. Eliminate these
conditions as indicated in the following chart.
SYMPTOM
CAUSE REMEDY
Intermittent Sparking
Improper fit of burner cap
into burner base
Seat cap in place.
Ceramic igniter is wet or
dirty
Carefully dry or
clean igniter.
Knob is left in the LITE
position
Clean ports in
burner cap with
a wire, a needle, or
straightened paper
clip.
Turn the knob to a
setting between HI
and SIM (LO on
earlier models)
Constant Sparking
Range is not properly
grounded
Have a qualified
electrician ground
the range properly.
Electrical power supply is
incorrectly polarized
Refer to installation
instructions for
correct installation