Carrier HRVCCSHA Ventilation Hood User Manual


 
2
OFF HIGHLOW
ARRET HAUTEBASSE
% D HUMIDITE RELATIVE HUMIDITY
20
25
30
40
50
60
70
80
OFF
ARRET
LOW
BASSE
INTERMITTENT
AIR EXCHANGE
ECHANGE D´AIR
´
ON
MARCHE
% HUM. RELATIVE HUM.
55%
45%
35%
30%
EXT. TEMP. EXT.
% D´HUMIDITE RELATIVE HUMIDITY
´
% HUM. RELATIVE HUM.
55%
45%
35%
30%
EXT. TEMP. EXT.
MODE
AIR EXCHANGE
ECHANGE D´AIR
´
20
25
30
40
50
60
70
80
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4°F
´
´
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4°F
OneTouch
TM
Control
Basic Control
Standard Control Automatic Control
(Not compatible with the following series:
HRVCCSHA and HRVCCSVA
)
INTERMITTENT
MAX
MIN
A05360
Fig. 2 -- Cont rols
SAFETY CONSIDERATIONS
Recognize safety information. This is the safety -- alert symbol
!
!
Whenyouseethissymbolontheunitandininstructionsormanuals,
be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.
DANGER identifies the most serious hazards which will result in
severe personalinjury ordeath.WARNINGsignifieshazardswhich
could result in personal injury or death. CAUTION is used to
identify unsafe practices which ma y resultinminorpersonalinjury
or product and property damage. NOTE is used to highlight
suggestionswhichwillresultin enhanced installation, reliability,or
operation.
OPERATING YOUR H EAT RECOVERY
VENTILATOR (HRV) WITH
ONETOUCHt CONTROL:
Press “PUSH” until the desired ventilation operation is selected.
Therearethreeselections:High,Low,Intermittent.The powerindi-
cator light indicates which mode has been selected.
High:This modeis recommended forthe removal of excesspollu-
tantsandhumidity .Theventilatorwilloperateatitsmaximumspeed
continuously. The power indicator light will be lit red when this
mode is selected.
Low: This mode is recommended for normal daily operation. The
ventilator will o perate at its minimum speed continuously. The
power indicator light will be lit yellow when this mode is selected.
Intermittent: This mode is recommended when the inside air is too
dry in the heating season or too humid in the cooling season. The
ventilatorwill operateatitsminimum speed for20minutesperhour
and be off for 40 minutes per hour. The power indicator light will
be lit green when this mode is selected.
Off:To turntheventilatoroff,press“Push”until the powerindicator
light is turned off.
OPERATING YOUR HEAT RECOVERY
VENTILATOR (HRV) WITH BASIC,
STANDARD AND AUTOMATIC CONTROL
Your HRV is designed to operate as an integral part of your total
heating and cooling system. With the exception of high capacity
models, which are available with standard controls only, all HRVs
offer 4 control options (See Fig. 2).
S
BasicControls:Allowtheusertomanuallysettheunittolow--
or high --fan speed as required to maximize comfort. Controls
may be unit mounted.
S
Standard Controls: Offer automatic dehumidistat control and
the option to select low speed or intermittent fan during
heating season.
S
Automatic Controls: In addition to the operational features
found with standard controls, automatic controls feature a
recirculation mode. Not for use with forced--air HVAC
systems.
FanSpeedControl—Enablesuserto modulatefanspeedfromlow
to high.
Dehumidistat Control—Allows the user to select the relative hu-
miditylevelatwhichtheunitwould changefanspeedtoavoidcon-
densation problems while heating during the winter months. (See
Table 1).
Continuous Mode—If the relative humidity inside the building is
lower than selected, air exchange would occur with the outside at
low speed.Iftherelativehumidity levelinsidethebuilding ishigher
than selected, air exchange would occur outside at high speed. This
ensures continuous air exchange for constant air quality.
Intermittent Mode—If the relative humidity inside the building is
lower than selected, no air exchange would occur, and the system
would turn of f.If the relative humidity inside the building ishigher
than selected, air exchange would occur with outsideat high speed.
Thisensuresminimum airexchange levelwhen thebuilding is un-
occupied to minimize operating cost.
Recirculation Mode—If the relative humidity i nside the building
islower than selected, indoorair wouldbe circulatedand filtered at
highspeed.Iftherelativehumidity insidethehouse ishigher anse-
lected, air exchange would occur with outside at high speed. This
ensures continuous movement and filtration of air for maximum
comfort.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before servicing system, always turn off main power to
system. Turn off accessory heater power if applicable.
There may be more than 1 disconnect switch.
!
WARNING