CDA 3Q9 Ventilation Hood User Manual


 
6
Installation
Your extractor can be used to filter and recycle the air within
your kitchen, or to extract the air outside. When extracting air
to the outside, the unit can be vented as shown in the diagram
below. Note that we recommend the use of ducting with a
diameter of 150mm. Ducting with diameters of 100mm or
120mm may be used, but performance will be reduced.
When installing this appliance over a CDA hob, the clearance
between the extractor and the hob must be equal to or
exceed 650mm. This instruction overrides the instructions
supplied with the CDA hob. (The height should be measured
from the top of the hotplates or burners)
Where the extractor is to be installed above a non-CDA hob,
the instructions supplied with the hob may dictate that the
height required above the hob is greater than 650mm.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm
Fitting your extractor to the wall:
Before commencing, remove both the grease filters.
Fig. 5
Fig. 4