Changing the light bulb
Disconnect the appliance from the power.
• Release the light cover by pressing on the hooks at the back of the cover, then slide it towards the back of the fridge to
remove it.
• Unscrew the light bulb to remove it and replace with a new bulb of the same rating (not more than 15W).
• Replace the light cover and reconnect the power.
Troubleshooting
If you have any problems with your appliance, you should check the troubleshooting prior to calling CDA Customer Care
to prevent unnecessary service calls and potential cost.
If the appliance is not working
• Check there is power to the appliance:
• The green light on the control panel is lit
• The house fuses are intact and the fuse in the plug has not blown.
• The thermostat is not set to 0
• The plug socket is functioning fine. To check this, plug another electrical appliance in to see if the socket is working.
The appliance is working, but not very well
• The appliance is not overloaded
• The thermostat is set to an appropriate temperature
• The doors are closing properly
• The cooling system at the rear of the appliance is clean and free of dust, and not touching the rear wall.
• There is enough ventilation at the side and rear walls
The appliance is noisy
• The appliance is level and stable
• The side and rear walls are clear, and there is nothing resting on the appliance
• The cooling gas in the refrigerator will make a slight bubbling noise, even when the compressor is not running
There is water in the lower part of the refrigerator compartment
• The drain hole in the channel at the back of the compartment is clear
• If the temperature warning light flashes, contact CDA Customer Care.