INFUSION TIME - OPTIONAL INFUSION TIME
## SECONDS
Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water
into the grinds during the Pre-Infusion process.
SOAK TIME – OPTIONAL SOAK TIME
## SECONDS
Description – The Soak Time is the amount of time that the system will wait between the end of the hot
water infusion period and the beginning of brewing.
PULSE BREW - OPTIONAL PULSE BREW
ON/OFF
Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing
(pulsing) hot water.
PULSE ON TIME -OPTIONAL PULSE ON TIME
## SECONDS
Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot
water during a Brew Cycle.
PULSE OFF TIME -OPTIONAL PULSE OFF TIME
## SECONDS
Description – The Pulse OFF Time is the amount of time that the system will wait between hot water
dispenses during a Brew Cycle.
DRIP TIME
DRIP TIME
### SECONDS
Description – The Drip Time is the amount of time that the system will wait after the completion of the
hot water dispense before signaling the end of the Brew Cycle. This allows time for any water remaining
in the funnel to drain out.
WATER TEMPERATURE WATER TEMP
### °F
Description – The Water Temperature is the required (set point) temperature of the water in the reservoir
tank.
TEMPERATURE SENSOR CALIBRATION TEMP SENSOR CAL
ARE YOU SURE ?
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed
water temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed
temperature to match the reference thermometer. Depress one of the
[Hidden] Keys when the calibration is complete.
TEMP SENSOR CAL
### °F
LOCKOUT TEMPERATURE LOCKOUT TEMP
### °F
Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow
a Brew Cycle to begin unless the water is above the Lockout Temperature.
SLEEP TIMER SLEEP TIMER
ON/OFF
Description – The Sleep Timer feature automatically reduces the water temperature to three degrees
above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.
WARMER POWER WARMER POWER
### %
Description – The Warmer Power feature allows the user to reduce the actual heating power of the