Cecilware JAVA 2-QB-DC Coffeemaker User Manual


 
Page 4
PROGRAMMING FOR AUTOMATIC DISPENSE
(See Door diagram)
1. Turn Power Switch ON (toggle switch inside door).
2. PRESS and HOLD [red] STOP Button with one hand.
3. PRESS and HOLD [green] DISPENSE Button with other hand.
4. RELEASE [red] STOP Button ONLY.
5. Continue to HOLD [green] DISPENSE Button until BUZZER
sounds, then RELEASE.
6. PRESS and RELEASE [green] DISPENSE Button.
Product begins dispensing.
When it reaches the “DESIRED VOLUME”,
7. PRESS and RELEASE [green] DISPENSE Button to SET
“DESIRED VOLUME”.
DISPENSE Button can be jogged to top off.
8. PRESS and HOLD [red] STOP Button for 5 Secs. to LOCK IN
“DESIRED VOLUME”.
Repeat steps 1 to 8 for each Dispense Button.
The Automatic Dispense Buttons are factory programmed to dispense
1.3 oz. of water per second.
NOTE:
Set programming for Cup Volume with cup shelf “DOWN”.
Set programming for Decanter Volume with cup shelf “UP”.
PRODUCT STRENGTH ADJUSTMENTS:
The JAVA 2-QBD units have variable speed control auger
motors with variable speed of 10 to 30 RPM.
Drink or Product Strength can be changed by adjusting the
Gram Throw Dial on inside door panel.
The Gram Throw is factory preset at approx. 2.2 gr. per 8 oz.
cup and 15.0 gr. per decanter.
The water flow rate adjustment for the dispense valve
should remain fixed at 1.3 oz per sec.
POWER SWITCH
RINSE/ SERVE SWITCH
DISPENSE BUTTONS
DRINK
STRENGTH
ADJUSTMENT
READY LIGHT
HEATING LIGHT
PROGRAMMI
NG
INSTRUCTION