Cisco Systems ASC-4E Convection Oven User Manual


 
#8701/2 Electric Convection Oven - Manual Control 3
S I T E I N S T A L L AT I O N
This appliance must be
installed in a location that will
permit the oven to function
for its intended purpose and
to allow adequate clearance
for ventilation, proper
cleaning, and maintenance
access.
1. Hood installation is recommended. (
CHECK
LOCAL CODES
).
2. The oven must be installed on a stable and
level surface.
3. DO NOT install this oven in any area where it may
be affected by any adverse conditions such as steam,
grease, dripping water, high temperatures, etc.
4. DO NOT store or use any flammable liquids or
allow flammable vapors in the vicinity of this
oven or any other appliance.
5. This appliance must be kept free and clear of any
combustible materials.
6. This appliance must be kept free and clear of
any obstructions blocking access for maintenance
or service.
I N S T A L L AT I O N S A F E T Y W A R N I N G
®
METAL PARTS OFTHIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
O
PERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
DO NOT store or use any
flammable liquids or allow
flammable vapors in the vicinity of
any appliance.
DO NOT LIFT OR MOVE THE
OVEN BY USING THE DOORS
OR THE DOOR HANDLES.
ASC-2E WEIGHT
NET: 250 lb (113 kg) EST. SHIP: 325 lb ( 147 kg) EST.
CRATE 44" H X 42" W X 42" D
DIME NSIONS: (1118mm x 1067mm x 1067mm)
MINIMUM ENTRY CLEARANCE 31" (787mm) UNCRATED
ASC-2E •DIMENSIONS: H x W x D
EXTERIOR: 32-1/8" x 30" x 30-1/8" (815mm x 762mm x 815mm)
INTERIOR: 20" x 15" x 21" (508mm x 381mm x 533mm)
ASC-4E WEIGHT
NET: 393 lb (178 kg) EST. SHIP: 438 lb ( 199 kg)
CRATE 40" H X 44" W X 53" D
DIME NSIONS: (1016mm x 1118mm x 1346mm)
MIN. ENTRY CLEARANCE 31-1/2" (800mm) UNCRATED
W/O LEGS
ASC-4E DIMENSIONS: H x W x D
EXTERIOR: 57-1/2" x 38" x 44-1/2" (1461mm x 965mm x 1130mm)
INTERIOR: 24" x 29-1/8" x 25" (610mm x 740mm x 635mm)
MINIMUM CLEARANCE REQUIREMENTS
BACK 0" (0mm)
LEFT SIDE 2" (51mm)
RIGHT SIDE 2" (51mm)
FROM GREASE PRODUCING EQUIPMENT 6" (152mm)
RECOMMENDED SERVICE ACCESS: 20" (508mm) RIGHT SIDE
Where automatically operated appliances are vented
through a ventilating hood or exhaust system
equipped with a damper or with a power means of
exhaust, provisions shall be made to allow the
equipment to operate only when the damper is open
to a position to properly vent the appliance and
when the power means of exhaust is in operation.
ACCORDANCE WITH NFPA 54 COMMONWEALTH OF
MASSACHUSETTS ONLY
.