Note: Consult local authorities for venting and installation requirements.
For supply connection use only copper wire suitable for at least 75
°
C (167
°F).
Compartment has capacity for:
Five, 12˝ x 20˝ x 2
1
2˝ deep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether
untreated or pre-treated, based upon 10 hours of use per day,
and a Daily Blowdown, are as follows:
T
OTAL DISSOLVED SOLIDS less than 60 parts per million
T
OTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
C
onsult a local water treatment specialist for an on site water
analysis for recommendations concerning steam generator
feed water treatment (if required), in order to remove or
r
educe harmful concentrations of minerals. The use of high-
ly mineralized water will mean that more frequent servicing of
the steam generator will be necessary. The fact that a water
s
upply is potable is not proof that it will be suitable for the
generator.
NO
TES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are
U.L/NSF#4 and CSA(AGA, CGA).
H
D
C
C1 C2
ELECTRICAL
W
A
TTS
VOL
TS PHASE WIRES
CYCLE
AMPS
SUPPL
Y CONNECTION
HER
TZ
WIRE SIZE (COPPER)
*
Standard Wattage
Thr
ee Phase - 9 kW Standar
d
9400 208 3 3 60 26.1 10
9400
240
3
3
60 22.6 10
9400 480 3 3 60 11.4 14
Optional Low Wattage
Thr
ee Phase - 6 kW option
6400 208 3 3 60 17.8 12
6400 240 3 3 60 15.4 12
6400
480
3 3 60 7.7 14
* For supply connection use only copper wire suitable for at least 75˚C. (167˚F).
W
A
TTS
VOL
TS PHASE WIRES
CYCLE
AMPS
SUPPL
Y CONNECTION
HER
TZ
WIRE SIZE (COPPER)
*
Standard Wattage
Single Phase - 9 kW Standar
d
9400 208 1 2 60 45.2 6
9400
240
1
2
60 39.2 8
Optional Low Wattage
Single Phase - 6 kW option
6400 208 1 2 60 30.8 8
6400 240 1 2 60 26.7 10