Cleveland Range 21-CGA-5 Convection Oven User Manual


 
(NOT TO SCALE)
SECT. IV PAGE 8
0707
Litho in U.S.A.
UTILITY CONNECTIONS
ELECTRIC
115V - 1 Phase
35 Watts
4 Amps
GAS COLD WATER DRAINAGE
C
D
35 psi minimum
60 psi maximum
1
4˝ Dia. NPTfor
Generator (for water
treatment connection)
1
4˝ Dia. NPT for
Condenser
1
1
4˝ Dia. IPS
Do not connect any other
units to this drain.
Drain line must be vented.
No PVC pipe for drain.
1/2˝ Dia. IPS
C
C
SUPPLY PRESSURE
NA
TURAL
PROP
ANE
4.00˝ W.C. minimum 12.00˝ W.C. minimum
14.00˝ W.C. maximum 14.00˝ W.C. maximum
Manufacturer must be notified if unit will be used above 2,000
ft. altitude.
15 — 12˝ x 20˝ x 2
1
2˝ Cafeteria Pans or
10 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
23 — 12˝ x 20˝ x 4˝ Cafeteria Pans
TOTAL CAPACITY
WATER QUALITY
REQUIREMENTS
The quality of water varies
greatly from region to
region. Steam equipment
generators must be
drained daily and chemi-
cally descaled periodically
t
o ensure proper operation.
T
o minimize service prob-
l
ems caused by the accu-
mulation of minerals and
chemicals in water review
the following quality guide-
lines with a local water
treatment specialist. Inlet
water that is beyond these
specified guidelines should
be treated to achieve these
acceptable limits. Total
Dissolved Solids less than
60 ppm, Alkalinity less than
20 ppm, Silica less than 13
ppm, pH factor greater
than 7.5, Chlorine less
than 30 ppm.
NO
TES
:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA(AGA, CGA).
CLEARANCE
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoin-
ing wall or equipment is over
30” high for service access)
Contact factor
y
f
or v
ariances to c
learances.
Electrical Supply Drain: 1-1/4˝ Dia. IPS Flue Gas Exhaust
Cold Water Supply for Condenser 1/4˝ Dia. NPT Inlet for Generator Deliming Solution
from Generator
Cold W
ater Supply for Generator. Gas Supply 1/2˝ Dia. IPS
1/4˝ Dia. NPT (for water treatment conn.)
Unit comes with a 40 Mesh Water Strainer
A
B
C
G
F
E
D