CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
MODELS: 24-CEM-24 24-CEM-48
24-CEM-36
Cleveland Standard Features
Cooking Capacity for up to six 12˝ x 20˝ x 2
1
2
˝ deep Cafeteria Pans.
Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.
Solid State Controls operate water level and safety functions.
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
Separate Main Power Switch for “On/Off”
Exclusive Steam Cooking Distribution System:
The exclu-
sive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment dis-
tributes heat evenly and is easy to keep clean. Creased top & bot-
tom enhance drainage. Cold Water Condenser for each
compartment maintains a dry steam. Fully insulated cooking com-
partment for thermal efficiency. Removable Stainless Steel Slide
Racks for easy cleaning.
Exclusive “Cool to the Touch” Compartment Door Design:
Free floating inner door with reversible door gasket provides
an air tight seal. Stainless Steel Slam/Latch Door Latch
mechanism provides greater reliability.
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
Modular Cabinet Base with Hinged Door
.
Electric Steam Generator: Automatic Water Fill on start up.
Automatic Generator Drain at shutdown: Contains a “Water
Jet” Spray Rinse Cleaning Cycle to keep drain clear.
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
Secondary Low W
ater Cut-Of
f, factory installed (CALE)
(Required for
AZ.
AR. CA. CO. CT
. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
Standard voltage 208 or 240 volts, 60 Hz, 3 phase.
All Controls are serviceable from the front.
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 24-
CEM- _____ , Electric Steam Generator, _____ KW, _____ volts, _____ phase, 3
wire. Solid State Controls operate timing, water level and safety functions.
Electric Steam Generator with Automatic Water Fill on start-up and Automatic
Blowdown with additional Manual Drain Valve, For each cooking compart-
ment: 60 minute Mechanical Timer, Manual Operation Mode and Cold Water
Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Right Hand Door Hinging, Controls on the Left (DHR)
Electronic Timer with Compensating Load Feature (ETC)
ON/OFF Steam Switch only for compartment controls (MC)
Cafeteria pans in depths of 1˝, 2
1
2˝, 4˝ and 6˝
Voltages other than standard
Power Take Off Kit (EPTO), Kettle Interconnecting Kit (IMK)
Correctional Packages
Stainless Steel Base Frame (FSS)
Compartment Door Steam Shut Off Switch (SCS)
Boiler Descaling Pump Kit (107142)
Water Filters
Short For
m Specifications
SECT. III PAGE 1
0707
Cleveland Classic Series
TWO COMPARTMENT, PRESSURELESS
ELECTRIC STEAM GENERATOR
24, 36 OR 48 KW, 24” WIDE CABINET BASE DESIGN
C
ONVECTION
STEAMERS