Cleveland Range 42-CKGM-300 Electric Steamer User Manual


 
(NOT TO SCALE)
SECT. III PAGE 20
1007
Litho in U.S.A
Right - 6”, Left - 6”, Rear - 6”
(12”
on control side if adjoining wall or
equipment is over 30” high for
service access)
For use in non-
combustible locations.
Contact factory for
variances to clearances
1 1/2” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).
A
CTUAL CAPACITIES:
K
ettle 6 gallons/23 liters or 192, 4 oz. servings.
Other size servings may be calculated.
E
ach compartment has capacity for:
Three, 12˝ x 20˝ x 2
1
2˝
or six, 12˝ x 20˝ x 1˝
d
eep Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality stan-
dards whether untreated or pre-treated, based
upon 10 hours of use per day, and a Daily
Blowdown, are as follows:
T
OTAL DISSOLVED
S
OLIDS less than 60 parts per million
T
OTAL ALKALINITY less than 20 parts per million
S
ILICA less than 13 parts per million
p
H FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on
site water analysis for recommendations concerning
steam generator feed water treatment (if required),
in order to remove or reduce harmful concentrations
of minerals. The use of highly mineralized water will
mean that more frequent servicing
of the steam
generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable
for the generator.
5.0 Amps
** Do not connect to GFI
outlet. See note below.