Cleveland Range HA-MKDL-100-CC Hot Beverage Maker User Manual


 
SECT. XIV PAGE 8
1201
Litho in USA
Cleveland Range reserves right of design improvement or modification,as warranted.
MINIMUM CLEARANCE
FOR KETTLES
FRONT 36"
SIDE 12"
REAR 12"
DIMENSIONS
MODEL A B C D E F ELECTRICAL PER KETTLE - R.P.M.
208V/3PH/60Hz
HA-MKDL-60-CC 32 1/2" 50 3/4" 47" 83" 29 1/2" 8" 12 AMPS 4-25
HA-MKDL-100-CC 38 5/16" 57" 52" 93" 35" 9" 15 AMPS 3-22
HA-MKDL-150-CC 43" 62" 57 1/2" 101" 40" 9" 25 AMPS 3-20
HA-MKDL-200-CC 48" 65 3/4" 62" 111" 45" 9" 25 AMPS 3-20
HA-MKDL-300-CC 53" 76 3/8" 67 1/2" 100" 50" 11" 30 AMPS 3-17
UTILITY CONNECTIONS
CHILLED CHILLED COLD
WATER WATER POTABLE HOT CONDENSATE AIR
MODEL INLET RETURN WATER WATER RETURN DRAIN INLET STEAM
HA-MKDL-60-CC 3/4" 3/4" 1/2" 1/2" 1/2" 3/4" 1/2" 3/4"
15 GPM 15 GPM 15 GPM 1 CFM 320 lbs/hr
HA-MKDL-100-CC 1" 1" 3/4" 3/4" 3/4" 1" 1/2" 1"
20 GPM 20 GPM 20 GPM 1 CFM 525 lbs/hr
HA-MKDL-150-CC 1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
20 GPM 20 GPM 20 GPM 1 CFM 780 lbs/hr
HA-MKDL-200-CC 1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
25 GPM 20 GPM 20 GPM 1 CFM 1050 lbs/hr
HA-MKDL-300-CC 1 1/2" 1 1/2" 3/4" 3/4" 1" 1 1/2" 1/2" 1 1/2"
30 GPM 20 GPM 20 GPM 1 CFM 1575 lbs/hr
** HOT FILL WATER IS OPTIONAL
65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED
**
ELECTRICAL POWER
TO AND FROM
CONTROL PANEL
CONTRACTOR
MUST CUT ENTRY
HOLE
•TOP OR BOTTOM
POWER ENTRY
RECOMMENDED
MUST USE PROPER
CONNECTIONS TO
MAINTAIN U.L.
LISTING
(NOT TO SCALE)