Cleveland Range HA-MKDL-60-CCT-RL Hot Beverage Maker User Manual


 
SECT. XIV PAGE 1
1201
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
SECT. XIV PAGE 10B
0907
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
QUICK DISCONNECT
FOR FOOD PUMP
G
12 1/2"
F
E
H
A
B
C
D
PLUMBING BOX
WITH REMOVABLE
ACCESS PANEL
POURING LIP AND
POURING DEFLECTOR
PLAN VIEW
SIDE VIEW
ADCR
DIMENSIONS
MODEL ABCDEFGHELECTRICAL (per kettle) R.P.M.
208V/ 3PH/60Hz
HA-MKDL-60-CCT-RL
59" 36 3/4" 22" 50" 83" 46" 5" 63" 15 AMPS 3-22
HA-MKDL-100-CCT-RL
72" 42" 25" 57" 95" 52" 5" 69" 18 AMPS 3-20
HA-MKDL-150-CCT-RL
75" 47 1/2" 29" 65" 105" 57" 5" 74" 18 AMPS 3-18
HA-MKDL-200-CCT-RL
80 1/2" 52" 32" 70 1/4" 115" 62" 5" 79" 25 AMPS 3-18
HA-MKDL-300-CCT-RL
92" 65 1/2" 34" 82" 106" 67" 5" 84" 25 AMPS 3-16
UTILITY CONNECTIONS
CHILLED CHILLED COLD
WATER WATER POTABLE HOT CONDENSATE AIR
MODEL INLET RETURN WATER WATER RETURN DRAIN INLET STEAM
HA-MKDL-60-CCT-RL
3/4" 3/4" 3/4" 3/4" 1/2" 3/4" 1/2" 3/4"
15 GPM 15 GPM 15 GPM 1 CFM 320 lbs/hr
HA-MKDL-100-CCT-RL
1" 1" 3/4" 3/4" 3/4" 1" 1/2" 1"
20 GPM 20 GPM 20 GPM 1 CFM 525 lbs/hr
HA-MKDL-150-CCT-RL
1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
20 GPM 20 GPM 20 GPM 1 CFM 780 lbs/hr
HA-MKDL-200-CCT-RL
1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
25 GPM 20 GPM 20 GPM 1 CFM 1050 lbs/hr
HA-MKDL-300-CCT-RL
1 1/2" 1 1/2" 3/4" 3/4" 1" 1 1/2" 1/2" 1 1/2"
30 GPM 20 GPM 20 GPM 1 CFM 1575 lbs/hr
HOT FILL WATER IS STANDARD
65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED
**
MINIMUM
CLEARANCE
FOR
KETTLES
FRONT 36"
S
IDE 12"
REAR 12"
E
LECTRICAL POWER
T
O AND FROM
C
ONTROL PANEL
CONTRACTOR
MUST CUT ENTRY
HOLE
TOP OR BOTTOM
P
OWER ENTRY
R
ECOMMENDED
MUST USE PROPER
C
ONNECTIONS TO
M
AINTAIN U.L.
L
ISTING
(NOT TO SCALE)
NOTES: The pressure drop is 12 to 15 PSI for steam and chilled water passing through the kettle.
Air must be dry, clean and free of oil.