SECT. XIV PAGE 12
0600
Litho in USA
Cleveland Range reserves right of design improvement or modification,as warranted.
DIMENSIONS
MODEL A B C D E F ELECTRICAL PER KETTLE - R.P.M.
208V/3PH/60Hz
IA-MKDL-60-CC 32" 52" 64" 45 1/2" 8" 24" 10 AMPS 6-35
IA-MKDL-100-CC 39" 58 1/2" 70" 49 1/2" 9" 28" 12 AMPS 6-35
IA-MKDL-150-CC 45" 63" 79" 52 1/2" 9" 30" 15 AMPS 6-32
IA-MKDL-200-CC 49" 67" 84" 57 1/2" 9" 32" 15 AMPS 6-32
IA-MKDL-300-CC 56" 79" 89" 62 1/2" 11" 36" 25 AMPS 6-32
UTILITY CONNECTIONS
CHILLED CHILLED COLD
WATER WATER POTABLE HOT CONDENSATE AIR
MODEL INLET RETURN WATER WATER RETURN DRAIN INLET STEAM
IA-MKDL-60-CC 3/4" 3/4" 1/2" 1/2" 1/2" 3/4" 1/2" 3/4"
15 GPM 15 GPM 15 GPM 1 CFM 320 lbs/hr
IA-MKDL-100-CC 1" 1" 3/4" 3/4" 3/4" 1" 1/2" 1"
20 GPM 20 GPM 20 GPM 1 CFM 525 lbs/hr
IA-MKDL-150-CC 1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
20 GPM 20 GPM 20 GPM 1 CFM 780 lbs/hr
IA-MKDL-200-CC 1 1/4" 1 1/4" 3/4" 3/4" 1" 1 1/4" 1/2" 1 1/4"
25 GPM 20 GPM 20 GPM 1 CFM 1050 lbs/hr
IA-MKDL-300-CC 1 1/2" 1 1/2" 3/4" 3/4" 1" 1 1/2" 1/2" 1 1/2"
30 GPM 20 GPM 20 GPM 1 CFM 1575 lbs/hr
** HOT FILL WATER IS OPTIONAL
65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED
**
ELECTRICAL POWER
TO AND FROM
CONTROL PANEL
• CONTRACTOR
MUST CUT ENTRY
HOLE
•TOP OR BOTTOM
POWER ENTRY
RECOMMENDED
• MUST USE PROPER
CONNECTIONS TO
MAINTAIN U.L.
LISTING
(NOT TO SCALE)
MINIMUM CLEARANCE
FOR KETTLES
FRONT 36"
SIDE 12"
REAR 12"