Cleveland Range IA-MKDL-300-CC Hot Beverage Maker User Manual


 
_______________________________________________________________________
_
INCLINED AGITATOR KETTLE
OPERATING AND CLEANING INSTRUCTIONS
OPERATING INSTRUCTIONS
Your kettle has been equipped with a control panel that has some or all of the following
functions:
12. Main POWER switch
13. Temperature control
14. 24 hour chart recorder
15. KETTLE RUN push button
16. Agitator speed control with variable settings
17. Agitator STOP/START
18. Potable water meter with OFF/ON switch and push button to add water
19. Manual COOL water switch
20. Kettle selector switch for CONTINUOUS, OFF, COOK
21. SIMMER switch
22. Product VALVE OPEN/CLOSED
Operating the Kettle
10. To operate the system the main power switch on the control panel must be turned
on. The temperature control computer will run through its diagnostics for about
one minute.
11. To set desired temperature, turn switch to COOK. This activates the temperature
controller. The temperature displayer and the actual temperature will appear. To
change the temperature set point, press the push button with “+” to raise or
increase the temperature or press the button with “-“ to decrease or lower the
temperature.
12. Push the button marked KETTLE RUN and the steam will come on to heat the
kettle and its contents until the set point temperature is reached. It will cycle off
and on to maintain the set point temperature.
13. To start the agitator, press the button marked AGITATOR START and a green
light will indicate the agitator is on.
14. To stop the agitator, press the red AGITATOR STOP mushroom button.
15. To change the speed of the agitator, turn the SPEED CONTROL knob to the right
to increase the speed or to the left to decrease the speed. As a safety precaution,
always turn the speed to “0” when kettle is not in use and before use.
16. To add ingredients to the kettle, push AGITATOR STOP button. Steam heating
will continue in the jacket and the agitator must be started again as soon as
possible or product might burn on the surface of the kettle.
17. CONTINUOUS STEAM is a manual override allowing steam into the kettle but
with no temperature control.
18. SIMMER allows maintenance to the set point temperature but gently introduces
heat into the kettle.