Cleveland Range KGL-80-T, KGL-40-SH Hot Beverage Maker User Manual


 
7
OPERATING INSTRUCTIONS
3
4
5
2
1
7
5
8
10
9 6
ITEM # DESCRIPTION FUNCTION
1. Low Water Indicator Light (Red) When lit, indicates that the kettle is low on water and will not operate
in this condition (see RESERVOIR FILL PROCEDURES on page #28.
2. On-Off Switch/ Turns kettle ON/OFF and allows the operator to adjust the kettle
Solid State temperature in increments from 1 (Min.) to 10 (Max.).
Temperature Control (see the TEMPERATURE RANGE CHART on page #8).
3. Heat Indicator Light (Green) When lit, indicates that the kettle's burner is on.
Cycles ON-OFF with burner.
4. Ignition Failure Indicator Light Indicates failure of heating system to ignite.
(Amber)
5. Vacuum/Pressure Gauge Indicate steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
6. Pressure Relief Valve This valve is used to vent the kettle and in the unlikely event there is
(not shown) an excess steam build-up in the jacket, this valve opens
automatically to relieve this pressure.
7. Water Level Sight Glass Displays water level in steam jacket.
8. Tilt Wheel Used for tilting the kettle on hand tilt models. In power tilt models
there is a toggle switch in same location.
9. Flue
10. Tangent Draw-Off Valve Used for draining product or wash water from kettle. It is supplied as
standard equipment on stationary kettles and is optional on tilting kettles
.
Operating Controls & Indicators