Cleveland Range PDM-3 Range User Manual


 
The Floor Drain must be
located outside the con-
fines of the equipment.
1 1/2” IPS common drain.
Do not connect other
units to this drain.
Do not use PVC pipe for
drain.
(NOT
T
O SCALE)
SECT
.
VI P
AGE
8
0707
Litho in U.S.A.
Each compartment has capacity for:
Eight, 12˝ x 20˝ x 2
1
2˝ Cafeteria Pans or
Six, 12˝ x 20˝ x 4˝ Cafeteria Pans or
Four, 12˝ x 20˝ x 6˝ Cafeteria Pans or
Four, 18˝ x 26˝ Bun Pans
Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com-
ply with those codes.
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, ULC, NSF,
and CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day
, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTALALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
Cleveland Range reserves right of design improvement or modification,as warranted.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)
Contact factory for
v
ariances to c
learances.