CMA Dishmachines L-1X16 Dishwasher User Manual


 
Maintenance
4.2. Quick service guide
MODEL L-1X & L-1X16 PARTS MANUAL Rev. 1.14 Page 11
MODELS: L-1X, L-1X16 UNDER COUNTER
TECHNICAL ISSUE CAUSE SOLUTION
Delimer switch in delime position Flip to
NORMAL
position
Wash Pump motor will not shut off Faulty delimer switch Replace switch, P/N 00475.30
Faulty manual drain switch Replace switch, P/N 03406.62
Faulty contactor Replace contactor, P/N 00404.82
Continues cycles Faulty #1 micro switch (start/stop) Replace switch, P/N 00411.00
Faulty start/fill switch Replace switch, P/N 03470.01
Faulty #1 micro switch Replace switch, P/N 00411.00
Low water level inside machine
Add water to tank to activate float switch, adjust
water cam on timer
Sustainer heater not working Faulty float switch Replace switch, P/N 13463.10
Machine not level Level machine
Faulty ice cube relay Replace relay, P/N 00631.00
Machine does not drain Faulty #3 micro switch (drain) Replace switch, P/N 00411.00
Faulty drain valve Replace drain valve, P/N 04103.00
Does not hold water Faulty #3 micro switch (drain) Replace switch, P/N 00411.00
Clogged or defective drain valve Clean and/ or replace drain valve, P/N 04103.00
Tank overflows overnight Debris in water Solenoid Valve
Clean and replace valve diaphragm, P/N
00707.00
Water leaks out of Vacuum Breaker
Dirty or defective vacuum breaker kit
assy
Clean or replace internal parts, P/N 03623.00
Faulty check valve Replace check valve, P/N 00715.00
Male/ female plug on the back of control
drawer is loose
Secure plug
Wash Pump motor not running Faulty door reed switch Replace reed switch, P/N 00557.55
Faulty 7th micro switch Replace switch, P/N 00411.00
Faulty motor contactor Replace contactor, P/N 00404.82
Faulty Start/Fill Switch Replace switch, P/N 03470.01
Timer does not rotate Faulty #1 micro switch Replace switch, P/N 00411.00
Faulty timer motor Replace motor assembly, P/N 00501.00
Faulty #4 Micro switch Replace switch, P/N 00411.00
Machine does not fill
Debris inside water solenoid valve or
Faulty valve
Clean and replace valve diaphragm, P/N
00707.00
Faulty water solenoid coil Replace solenoid coil, P/N 00738.10
Delimer switch in wrong position Switch to
NORMAL
position
Sanitizer pump does not run Faulty 5th micro switch Replace switch, P/N 00411.00
Faulty sanitizer pump motor Replace motor, P/N 00416.00