ColdTech CFD-3F Refrigerator User Manual


 
ColdTech® Refrigerator Settings
Temperature set to 37 F
Parameter Function Set Range Default
E1 Lower Setpoint Limit -40 F ~ set temp 36 F
E2 Higher Setpoint Limit set temp ~ 120 F 45 F
E3 Hysteresis, temp. variance 1 ~ 18 F 10 F
E4 Comp. start delay time 0 ~ 10 min. 2 min.
E5 Offset on room temp -5 ~ 5 F 0 F
E6 Offset on evap temp -5 ~ 5 F 0 F
F1 Max. defrost duration 1 ~ 60 min. N/A
F2 Defrost interval time 0 ~ 24 hr. 0
F3 Defrost termination temp 32 ~ 68 F N/A
Key
F = Farenheit (degrees)  temp = temperature
min. = minutes max = maximum
hr. = hours N/A = not applicable
Warning:
Do not change the default settings of your ColdTech unit
without consulting a qualified service technician or the
ColdTech service department.
-9-
Applicable to Models: CFD-1R, CFD-2R, CFD-3R