Coway CHP-03AR Water Dispenser User Manual


 
WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET
|
CHP-03AR
Others
Water Filtration System Performance Data Sheet
Brand: Mach Model: CHP-03AR
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 27.7 95.7 96.3
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
POSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.32 0.0077 95.70 97.6
POSTCARBON ≥95%reduction 0.298 0.005 96.0 98.3
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER
229gallons(forVOC)
6,103gallons(forAestheticChlorine)
POST-CARBONFILTER
212gallons(forVOC)
1,179gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm
2
)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow
0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 82.3GPD
ProductEciencyRating 39.2%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L
30