TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1. Yellow light at switch does NOT light.
1a. Circuit breaker/fuse to wall outlet blown.
2a. Cord is unplugged from wall outlet.
3a. Switch is “OFF.”
2. Unit does not get hot.
2a. Thermostat set too low or are off.
2b. Switch is “OFF.”
3. Unit gets too hot or won’t shut off
3a. Defective electrical parts.
3b. UNPLUG UNIT FROM WALL OUTLET
4. Blower does not work or makes noise. 4a. Defective Blower
5. Excess moisture in cabinet.
5a. Foods taken from oven or fryer should be “slacked
out” for 5 minutes before placing in hot cabinet.
NOTE: Optional digital thermometer will ash if cabinet temperature is below 140°F or above 250°F.
Call the Factory if you need different settings.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
REPLACEMENT PARTS:
CABINET PARTS:
DESCRIPTION 120 VOLT 240 VOLT DESCRIPTION PART NO.
Hot Unit HU18671-184* HU18671-185 Door Latch Kit 1006-143-K
Terminal Block 0852-091 0852-091 Latch Strike 1006-144-K
Blower Kit 0769-180-K 0769-182-K Door Gasket, CCB-96A 0861-173
Heater Kit 0811-214-01 0811-215-01 Door Gasket, CCB-120A 0861-172
Thermostat Kit 0848-062-K 0848-062-K Door Hinge 0519-084
Thermometer Kit 5238-030-K 5238-030-K Push Handle 1072-089
Power Cord 0810-029-02* 0810-039-03 Wire Grid 1170-095
Switch Kit 0808-118-K 0808-118-K Door Assembly, CCB-96A 1221-460-K
Door Assembly, CCB-120A 1221-461-K
For Canadian Use:*
Hot Unit (120 Volt) HU18671-184C
Power Cord Plug 0713-017
Thermometer Kit, °C 5238-024-01