Cres Cor CO151F1818 Convection Oven User Manual


 
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Ovens
FL-2202-MP-M
Rev. 1 (4/08)
Page 3 of 10
HOW TO INSTALL CABINETS:
Remove all packing material from inside cabinet.
Install the cabinet interior (pan slides).
Place hot unit (shipped separately) on the top of the
cabinet. Caution: Hot unit is heavy, be sure to have
plenty of help during installation.
Plug power cord into wall receptacle.
1.
2.
3.
4.
INSTALLATION INSTRUCTIONS
VENTING YOUR OVEN:
The purpose of ventilating hoods is to direct and
capture smoke, grease-laden vapors, heat, odors, or
fumes.
Low temperature equipment (maximum temperature
250°F/121°C) does not produce heat, odors, fumes,
grease-laden vapors or smoke and is not required to be
vented.
1.
2.
Most jurisdictions consider our low-temperature ovens
(maximum temperature is 350°F/177°C) as low-heat
appliances not requiring vent hoods.
Installation must conform with local codes. The
authority having jurisdiction of enforcement of
the codes will have the responsibility for making
interpretations of the rules.
3.
4.
HOT UNIT SPECIFICATIONS:
MODELS with FOUR (4) HEATERS at 2000 Watts each (Total: 8200 Watts.)
MODEL NOS. *
ELECTRICAL SPECS
(AC SERVICE)
ELEC. LOAD POWER SUPPLY REQUIREMENT
Volts Ph Hz. Amps Volts Amps Ph Wire Volts NEMA
HU-18-671-120-MP
HU-18-671-122-MP
208 1 60 39 208 50 1 3 208 6-50P
HU-18-671-121-MP
HU-18-671-123-MP
240 1 60 34 240 50 1 3 240 6-50P
MODELS with THREE (3) HEATERS at 2000 Watts each. (Total: 6200 Watts.)
HU-18-671-138-MP
HU-18-671-142-MP
208 3 60 18 208 30 3 4 208 L15-30P
HU-18-671-139-MP
HU-18-671-143-MP
240 3 60 16 240 30 3 4 240 L15-30P
MODELS with THREE (3) HEATERS at 1500 Watts each. (Total 4700 Watts.)
HU-18-671-124-MP
HU-18-671-137-MP
208 1 60 23 208 30 1 3 208 6-30P
HU-18-671-125-MP
HU-18-671-127-MP
240 1 60 20 240 30 1 3 240 6-30P
HU-18-671-140-MP
HU-18-671-144-MP
208 3 60 13 208 20 3 4 208 L15-20P
HU-18-671-141-MP
HU-18-671-145-MP
240 3 60 12 240 20 3 4 240 L15-20P
*NOTE: Suf x “F” for 5 preset keys, “T” for 10 preset keys. All models are designed for AC Service.
To install stacking units, refer to instruction sheet
FL-2211, “STACKING INSTALLATION”.
CAUTION