Dacor DO130 Oven User Manual


 
PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
1.10
Single, Distinctive
Wall Oven
DO
1 1/2”
(3.8 cm)
typical counter
1“ (2.5 cm) Min.
to combustible floor
3/4” (1.9 cm)
support platform
1“ (2.5 cm) Min. to combustibles
Recommended
electrical
location
4” typical toe kick
36”
(91.4 cm)
P
R
SINGLE WALL OVEN - INSTALLED UNDER COUNTER
Recommended
electrical
location
Alternate
electrical
location
4” typical toe kick
N
P
R
3/4” (1.9 cm)
support platform
31 1/4” (79.4 cm)
recommended
1” (2.5 cm) Min.
to bottom of
cabinet door
1” (2.5 cm) Min.
to top of
cabinet door
SINGLE WALL OVEN - CUTOUT DIMENSIONS
Model Number
(N) Minimum
Cabinet
Width
(P) Minimum
Cut Out Width
(R) Minimum
Cutout Height
DO130
30”
(76.2 cm)
28 ½”
(72.4 cm)
27 5/8”
(70.2 cm)
Minimum Interior Cabinet Depth: 24” (61.0 cm)
Cabinet/countertop tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PG01 - 007 Revised 12/15/09 Page 2/2