Dacor DR30GIFS Ventilation Hood User Manual


 
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
30” Wide
All Gas Ranges
Document # PG05-007
Revised 04/04/13 Page 5/5
12 1/4”
(31.1 cm)
to
14 1/4”
(36.2 cm)
4 1/4”
(10.8 cm)
10” (25.4 cm)
10” (25.4 cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
BACK OF RANGEUTILITY CLEARANCE BEHIND RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural 5” 6” 1/2 psi
LP 10” 11” 1/2 psi
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load
120 Vac, 60 Hz, 15 Amps.,
dedicated, grounded
4.0 Amps. @
120 Vac, 60 Hz
IMPORTANT: The information above is for reference only. If the above
data does not agree with the product data label, use the data on the
product data label.
The gas inlet on the regulator accommodates a 1/2” NPT gas line
connection. The range can also accommodate a 3/4” NPT gas line
connection by removing the 1/2” to 3/4” adapter on the regulator inlet.
6’ (183 cm)
long
STANDARD WIDTH CUTOUT FOR MODEL DR30DI[F]S
SELF-RIMMING TRIM KIT ATKDR30GW REQUIRED
Electrical Specifications/Dimensions, All Models
Self-Rimming Installation, Standard Cutout Requirements (Models DR30GIS and DR30GIFS Only)
Non-combustible
rear wall required
30” (76.2 cm)
countertop/cabinet opening
below countertop
Countertop front
Cabinet face
10” min. (25.4 cm)
to any combustibles
above counter both sides
24 3/8”
min.
(61.9 cm)