Dacor ER30DSR Range User Manual


 
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.8
Epicure™ Ranges
ER30D/ER30DSR
103107
24” Typ.
(610mm)
25” Typ.
(635mm)
F
G
All tolerances: +1/16”, -0 (+1.6mm, -0)
CUT-OUT DIMENSIONS
“F” “G”
36” (914mm)*
30” (762mm)**
30
1
/
16
” (916mm)*
* Recommended
** Minimum
2/3
Gas and Electrical Service
The shaded area shown denotes the location of the gas ◊
inlet and the electrical junction box/receptacle. This is the
recommended location. For replacement purposes, the
location of the existing utilities may be utilized provided they
do not interfere with the sides or rear of the range. Check
local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between ◊
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. ◊
Access to the remote circuit breaker panel/fuse box, when ◊
the range is in place.
The gas supply piping and shut-off valve, and the electrical ◊
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located ◊
so that the range can be pulled out for service while the
appliance remains connected.
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
Non-Combustible
Rear Wall
Combustible Side
Wall Above Range
Countertop
Opening
29 1/4” (743mm)
30 1/16” (764mm)
Cabinet
Opening
23 9/16”
(598mm)
7/16”
(11mm)
10” Min.
(254mm)
Both Sides
1”
(25mm)
Rear Wall
Countertop
Opening
29 1/4” (743mm)
ERV Opening
27 7/8” (708mm)
Minimum Cabinet depth: 27 1/8” (688mm)
Minumum Countertop depth: 28 1/8” (714mm)
30 1/16” (764mm)
Cabinet
Opening
24 1/16”
(611mm)
2 13/16” (71mm)
1”
(25mm)
1/4” Min.
(6mm)
Combustible Side
Wall Above Range
10” Min.
(254mm)
Both Sides
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
wIth ERv RAISED vENt
CAbINEt CUt-oUt DIMENSIoNS