Dacor ER48D Cooktop User Manual


 
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.16
Epicure
®
Ranges
ER36D, ER48D
2/2
CUT-OUT DIMENSIONS
Range Model “F” “G” “H”
ER36D
42” (1067mm)*
36” (914mm)**
36 1/16”
(916mm)**
33 1/2”
(848mm)
ER48D
54” (1372mm)*
48” (1219mm)**
48 1/16”
(1221mm)**
43 1/2”
(1102mm)
* Recommended
**Minimum
Gas and Electrical Service
For replacement purposes, the location of the existing utilities ◊
may be utilized provided they do not interfere with the sides or
rear of the range. Check local building codes for permissible
locations.
An external manual shut-off valve must be installed between ◊
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. ◊
Access to the remote circuit breaker panel/fuse box, when the ◊
range is in place.
The gas supply piping and shut-off valve, and the electrical ◊
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located so ◊
that the range can be pulled out for service while the appliance
remains connected.
Revised
03/10/09
3
2, 5
F
G
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
4
Consult local code for exact location requirements.
5
Not applicable for cabinets more than a horizontal
distance of 10” (254mm) from the edge of the range.
1
Vertical to combustibles directly above cooking surface;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
Measured from range top panel.
Non-combustible
surface along
back wall
recommended
30” (762mm)
Min.
1
36 1/2”
(927mm)
Max.
13” (330mm)
Max.
5
Suggested
location of
utilities
4
G
10" (254 mm) Min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum Countertop Height:
30 1/4” (768 mm)
Maximum Countertop Height:
36 1/2” (927 mm)
rear wall recommended
Backsplash
3/8" (10 mm)
Min. flat countertop
overhang
H
2 13/16"
(71.4 mm)
3
CUTOUT WITH OPTIONAL ERV RAISED VENT
(TOP VIEW)
APPROVED RAISED VENT MODELS
Raised Vent Model
For use with
Range Model
ERV36-ER ER36D
ERV48-ER ER48D
Stiffener
Cabinet face**
Countertop*
* IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT”
for countertop cutout dimensions.
** IMPORTANT: Cabinet face must not stick out further than
back of control panel.
Back of
control
panel
ERV36-ER or
ERV48-ER
raised vent
ER36D or ER48D Range
3/8” Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Countertop height:
30 1/4" (768 mm) Min.
36 1/2” (927 mm) Max.
RAISED VENT INSTALLATION SIDE VIEW
Tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated