4.10
SGM304, SGM365, SGM466
13"
(330mm)
Max.
A
3 1/8" Min.
(79mm)
30"
(762mm)
Min.
Clearances to Combustibles
18"
(457mm)
Min.
Model
“A”
Minimum
“A”
Maximum
SGM304 30” (762mm) 36” (914mm)
SGM365 36” (914mm) 42” (1067mm)
SGM466 48” (1219mm) 54” (1372mm)
Model
“B”
Minimum
SGM304 29” (737mm)
SGM365 35 1/4” (895mm)
SGM466 46” (1168mm)
1/4” (6mm)
Mimimum clearance
to combustible
surfaces
B
Under Cabinet Clearances - Front View
30”, 36”, 46” Wide,
Preference™ Gas Cooktops
2/2
NOTES:
1. Factory installed liquid propane (LP) special
ordered.
2. Cooktop is supplied with a 48” (1219mm) power
cord, with a three prong grounded plug.
3. Utilities are located in the right rear corner of the
cooktop.
4. See the Combination Installation (CI) section if
installing with a downdraft, wall oven, or warming
oven.
Revised
07/18/08
SGM304
SGM365
SGM466
SGM304LP
SGM365LP
SGM466LP
Gas Type Natural Gas LP Gas
Manifold
Pressure
5” Water Column
10” Water
Column
Min. Gas Supply
Pressure **
6” Water Column
11” Water
Column
Total Connected
Load
0.25 Amps
(0.03 kW)
0.25 Amps
(0.03 kW)
Circuit
Requirement
120 Vac,
60 Hz, 15 Amp
120 Vac,
60 Hz, 15 Amp
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.