PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Mark the following safety checks on all ovens to be serviced before activating the magnetron or other micro-
wave source, and make repairs as necessary: (1) Interlock operation, (2) proper door closing, (3) seal and
sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5)
evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating com-
partments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity,
and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
TABLE OF CONTENTS
PROPER USE AND SERVICE PRECAUTIONS 3
SPECIFICATIONS 4
FEATURE DIAGRAM 5
INSTALLATION 6
OPERATION 7
MEASUREMENT OF THE MICROWAVE OUTPUT POWER 8
MICROWAVE RADIATION TEST 9
KOR-6115 WIRING DIAGRAM 10
KOR-61151 WIRING DIAGRAM 11
CIRCUIT DESCRIPTION 12
PRECAUTIONS FOR DISASSEMBLY AND REPAIR 14
DISASSEMBLY AND ASSEMBLY 15
INTERLOCK MECHANISM 20
TROUBLE SHOOTING GUIDE 22
COMPONENT TEST PROCEDURE 24
EXPLODED VIEW AND PARTS LIST 26