5. To remove control panel parts.
1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
2) Remove the door open lever from the control panel.
3) Remove four screws which secure the PCB assembly to control panel.
4) Disconnect membrane tail from the connector of the PCB assembly.
5) Detach membrane from the control panel.
6) Remove door open button and button spring from the control panel.
7) Reverse the above steps for reassembly.
REF NO. PART CODE PART NAME DESCRIPTION Q’TY REMARK
B01 3518520960 SWITCH MEMBREANE KOR-63DB9S 1 KOR-63DB
3518520970 SWITCH MEMBRANE KOR-63FB9S 1 KOR-63FB
B02 3516725300 CONTROL PANEL ABS SG-0760D, SG-175 1 KOR-63DB
3516725350 CONTROL PANEL ABS SG-0760D, SG-175 1 KOR-63FB
B03 3514320670 PCB AS KOR-63DB9S 1
B04 7122401211 SCREW TAPPING T2S TRS 4X12 MFZN 3
B05 3513702710 LEVER DOOR OPEN PP 1
B06 441G430171 SPRING BUTTON SWP DIA0.7 1
B07 3516906940 BUTTON DOOR OPEN ABS SG-0760D, SG-175 1 KOR-63DB
3516906950 BUTTON DOOR OPEN ABS SG-0760D, SG-175 1 KOR-63FB