Daewoo Microwave Oven Microwave Oven User Manual


 
25
1. CIRCUIT CHECK PROCEDURE
1. Low Voltage Transformer check
The low voltage transformer is located on the P.C.B.
Measuring condition: input voltage : 230V/Frequency : 50Hz
2. Voltage check
Key check point
Check method
PRINTED CIRCUIT BOARD
NO CHECK POINT REMARK
1 IC 1 PIN 14 -5 VDC
2 IC 1 PIN 22
3 IC 1 PIN 1 OR 2
NOTE :
Each measure point must be measured with GND points.
NOTE :
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
Terminal Voltage
4-8
LOAD
AC 25.8 V
NO LOAD
AC 31.8 V
NO MEASURE POINT WAVE FORM REMEDY REMARK
1 MP1 DC -5V±0.25V Replace VL1, EC1 NO LOAD
2 MP2 DC -12V±2.0V Replace EC2, D9, 10, 11 NO LOAD
T:20ms(50Hz)
T:250ns(4MHz)