10
Plug
OVERFLOW CONDITIONS:
The dishwasher is designed to detect/monitor water overflow conditions. The overflow tube is located in the lower (well)
section of the inner door liner. This tube must be kept free and clear of obstructions and debris. In the event of an overflow
condition, the water level rises above the height of the overflow tube and is directed into the overflow container.
(located behind lower kick-plate)
When the water level reaches a predetermined height, the float switch is activated closing power to the water inlet valve and
automatically turns on the pump to evacuate the water inside the tub only. The accumulated water inside the float container
must be discharged manually before the dishwasher can be re-started. To empty the float container, follow the instructions below.
PORTABLE DISHWASHER (MODEL):
• Disconnect the dishwasher from the electrical power supply.
• Disconnect the hose assembly from the faucet (water) supply.
• Keep the dishwasher upright at all times.
• The overflow container (water plug) is located behind the lower kick-plate. (See Fig. 1)
• Remove 4 screws from the underside of the kick-plate.
• Pull the kick-plate toward you. This will require applying a little force.
• Remove the black rubber “plug” located at the front bottom of the metal plate. (See Fig. 2)
• Allow the water to drain into a cup/container.
• Replace the rubber “plug”, making sure it is secure.
• Replace the lower kick-plate. (snap into position)
• It is not necessary to replace the 4 kick-plate screws removed earlier.
The dishwasher is now ready to be restarted.