Defy Appliances 600STW Oven User Manual


 
INSTALLATION
Note: The oven cavity must vent through the front only. Avoid gaps between the
cavity sides and the underside of the worktop
Insert the oven into the cupboard.
Open the door to expose the fixing holes in the side trims.
Secure the oven by 4 countersunk screws (fasteners are not supplied).
The hob should be installed in a ventilated cupboard fitted with a sturdy worktop.
Secure the hob using the fixing brackets provided.
UNDER-COUNTER INSTALLATION for models 600S, ST (C optional)
Worktop
32mm - 48mm thick
Vent
gap
at
front
only
100
590
Aperture
(210)
Floor
Datum
900
565 Aperture
Top filler piece
Typical section showing
ventilation requirements
Aperture
590 H x 565 W x 570 D
6
+
_
3
0
+
_
3
0
+
_
3
0
UNDER-COUNTER INSTALLATION model 600STW
Worktop
32mm - 48mm thick
For 32mm thick top
No filler piece will be
required when a
48mm thick top is used.
Datum
900
565 Aperture
Top filler piece
Aperture
840 H x 565 W x 570 D
60
Vent
gap
at
front
only
6
+
_
3
0
Levelling feet are provided to assist you in
positioning the oven so that it stands firm
and level.
To adjust, tilt the oven back slightly and
turn the relevant foot to either raise or lower
the oven.