The lower duct fits over the extractor
hood motor assembly and over the upper
duct. Take care not to scratch or damage
the hood and upper duct surfaces.
Loosely attach the lower duct bottom
edge to the hood by four self tapping
screws through four holes on the inside
of the extractor hood .
TOP CHIMNEY DUCT
CEILING MOUNTING BRACKET
Before fitting the chimneys, connect up
the outlet ducting (if required) and insert
the fitted plug into the wall socket.
Remove the protective film from the
chimney ducting taking care not to dam-
age the polished stainless steel surface.
Fit the upper chimney duct section (the
one with louvre outlets) to the ceiling
mounting bracket using the screws sup-
plied.
INSERT 6 SELF TAPPING SCREWS
Fit the lower chimney duct to the lower
wall mounting bracketand tighten the six
screws on the inside of the extractor hood
Drill 3.5mm Dia. holes through the top
holes in the bottom chimney and through
the lower end of the top chimney duct.
Fasten the two chimneys to the centre
chimney bracket.
Top chimney duct
Drill two 3.5mm Diameter
holes and secure two chimney
ducts to mounting bracket.
Bottom chimney duct
Mounting bracket