Delfield F18BC Freezer User Manual


 
F18 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
4
Delfield
®
Specifications
MODEL # OF SHELF AREA # OF RECOMMENDED VOLTS/HERTZ/ BTU DESIGN EVAP. CAP.
NUMBER DOORS SQ. FT. PANS HORSE POWER PHASE AMPS BASE/RAIL BTU/°TD
Remote Refrigerated Salad Top Tables
F18SR31A (1) 19” 2.56 6 1/4 115/60/1 3.0 280/265 120
F18SR44A (2) 19” 5.12 6 1/4 115/60/1 3.0 491/441 120
F18SR44B (2) 19” 5.12 8 1/4 115/60/1 3.0 491/441 120
F18SR44C (2) 19” 5.12 10 1/4 115/60/1 3.0 491/441 120
F18SR52A (1) 19” & (1) 27” 6.51 6 1/4 115/60/1 3.0 532/529 120
F18SR52B (1) 19” & (1) 27” 6.51 8 1/4 115/60/1 3.0 532/529 120
F18SR52C (1) 19” & (1) 27” 6.51 10 1/4 115/60/1 3.0 532/529 120
F18SR52D (1) 19” & (1) 27” 6.51 12 1/4 115/60/1 3.0 532/529 120
MODEL # OF SHELF AREA # OF VOLTS/HERTZ/ BTU DESIGN BTU SYSTEM CAP.
NUMBER DOORS SQ. FT. PANS HORSE POWER PHASE AMPS BASE/RAIL BASE/RAIL
Self-Contained Refrigerated Salad Top Tables
F18SC39A (1) 19” 2.56 6 1/4 115/60/1 10.0 280/265 1903/745
F18SC39B (1) 19” 2.56 8 1/4 115/60/1 10.0 280/353 1903/867
F18SC52A (2) 19” 5.12 6 1/4 115/60/1 10.0 444/265 1903/745
F18SC52B (2) 19” 5.12 8 1/4 115/60/1 10.0 444/353 1903/867
F18SC52C (2) 19” 5.12 10 1/4 115/60/1 10.0 444/441 1903/971
F18SC52D (2) 19” 5.12 12 1/4 115/60/1 10.0 444/529 1903/1061
F18SC60A (2) 19” & (1) 27” 6.51 6 1/4 115/60/1 10.0 515/265 2314/667
F18SC60B (2) 19” & (1) 27” 6.51 8 1/4 115/60/1 10.0 515/353 2314/798
F18SC60C (2) 19” & (1) 27” 6.51 10 1/4 115/60/1 10.0 515/441 2314/916
F18SC60D (2) 19” & (1) 27” 6.51 12 1/4 115/60/1 10.0 515/529 2314/1023
A 5-15P NEMA plug is used on self-contained units
MODEL # OF STORAGE SHELF AREA # OF RECOMMENDED VOLTS/HERTZ/ BTU DESIGN LOAD EVAP. CAP.
NUMBER DOORS CU. FT. SQ. FT. PANS HORSE POWER PHASE AMPS BASE/RAIL BTU/°TD
Remote Refrigerated Reduced Height Rail
F18DR44 (2) 19” 9.49 5.12 10 1/4 115/60/1 3.0 547/441 120/19
F18DR52 (1) 19” & (1) 27” 11.81 6.51 12 1/3 115/60/1 3.0 625/529 120/23
F18DR60 (2) 27” 14.14 7.9 16 1/3 115/60/1 5.0 703/617 120/26
F18DR70 (2) 32” 17.05 9.64 18 1/2 115/60/1 5.0 800/794 120/32
F18DR79 (1) 19” & (2) 27” 18.68 10.29 18 1/2 115/60/1 5.0 962/882 240/36
F18DR87 (3) 27” 21.30 11.85 22 3/4 115/60/1 5.0 1032/970 240/39
MODEL # OF STORAGE SHELF AREA # OF VOLTS/HERTZ/ BTU LOAD BTU SYSTEM CAP.
NUMBER DOORS CU. FT. SQ. FT. PANS HORSE POWER PHASE AMPS BASE/RAIL BASE/RAIL
Self-Contained Refrigerated Reduced Height Rail
F18DC52 (2) 19” 9.49 5.12 12 1/4 115/60/1 10.0 547/529 1903/1061
F18DC60 (1) 19” & (1) 27” 11.81 6.51 14 1/3 115/60/1 12.0 625/617 2314/1121
F18DC68 (2) 27” 14.14 7.9 18 1/3 115/60/1 12.0 703/794 2314/1544
F18DC82 (2) 32” 17.05 9.64 20 1/2 115/60/1 14.0 800/882 3097/1648
F18DC91 (1) 19” & (2) 27” 18.68 10.29 22 1/2 115/60/1 14.0 962/1058 3807/1839
F18DC99 (3) 27” 21.30 11.85 24 3/4 115/60/1 16.0 1032/1147 5286/2191
A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99.