INSTALLATION NOTE:
Refrigeration system is designed so that air will flow under the
unit, through the compressor area and out the front of the unit.
Any restriction to this air flow path will void the warranties.
PLEASE NOTE:
Air flow through the louver on the back of the unit is not
necessary for operation, however, any air which passes through
the louver is beneficial.
Deleld reserves the right to make changes to the design or specications without prior notice.
Model
Number of
Doors
1/6 Size
Pans
Storage
FT
3
Shelf
Area FT
2
H.P. V/Hz/Ph Amps
Nema
Plug
Ship Weight
Lbs/Kg
BTU Load
Base/Rail
BTU Capacity
Base/Rail
F18RC52
(2) 19” 12 9.49 5.12 1/4 115/60/1
10.0 5-15P 520/236 547/529 1903/1061
F18RC60
(1)19” & (1)27” 14 11.81 6.51 1/3 115/60/1
12.0
5-15P 560/254 625/617 2314/1121
F18RC68
(2) 27” 16 14.14 7.90 1/3 115/60/1
12.0
5-15P 650/294 703/794 3097/1544
F18RC82
(2) 32” 20 17.05 9.64 1/2 115/60/1
14.0
5-20P 720/326 800/882 3097/1648
F18RC91
(2) 27” & (1)19” 22 18.68 10.29 1/2 115/60/1 14.0
5-20P 750/340 962/1058 3807/1839
F18RC99
(3) 27” 24 21.30 11.85 1/2 115/60/1
14.0
5-20P 775/351 1037/1147 5286/2191
52" (132cm)
14" (35.6cm)
60" (152.4cm)
18" (45.7cm)
82" (208.3cm)
91" (231.1cm)
99" (251.5cm)
31.5"
(80 cm)
31.5"
(80 cm)
J = Junction Box W/8FT (2.4M) Cord & Plug
C = Condensing Unit
Mechanical Detail
C
J
J
C
68" (172.7cm)
NOTE: Unobstructed Airflow Must Be Maintained To Insure
Unit Performance And Maintain Warranty.
6.13"
[15.6cm]
7.62"
[19.4cm]
36"
[91.4cm]
17"
[43.1cm]
Clearance
25"
[63.5cm]
Clearance
30"
[76.2cm]
Clearance
19" [48.3cm]
Door
27" [68.6cm]
Door
32" [81.3cm]
Door
End View
All Models
26.31"
[66.8cm]
24"
[61cm]
42"
[106.7cm]
6"
[15.2cm]
14.29"
[36.3cm]
Pan Cover, When Open, Extends
To a Height of 12" [30.5cm]
F18RC
Reduced Height Raised Rail Self-Contained Prep Table