support.dell.com Dell PowerEdge Cluster FE100/FL100 Platform Guide 9
•
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 1.
)-$*
The following list provides PCI slot assignment information for the system’s PCI
buses, RAID controllers, HBAs, and the DRAC 2.
•
PCI buses
— PCI bus 0: PCI slot 1 and 2 are 64-bit, 33-MHz.
— PCI bus 1: PCI slots 3 through 6 are 64-bit, 33-MHz.
— PCI bus 2: PCI slots 7 and 8 are 64-bit, 33/66-MHz.
— PCI bus 3: PCI slots 9 and 10 are 64-bit, 33/66-MHz.
•
RAID controllers
— Install the RAID controller for the server’s internal drives in PCI slot 1.
•
HBAs
— Dell recommends installing the HBAs on separate PCI buses (PCI buses 2
and 3) to balance the load on the system.
•
DRAC 2
— If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 2.
96etttb0.book Page 9 Thursday, July 6, 2000 9:36 AM