DeLonghi 24 SS Oven User Manual


 
26
This appliance must be connected to a grounded, metallic permanent wiring sys-
tem or a ground connector should be connected to the ground terminal or wire
lead on the appliance.
This appliance is manufactured with a frame connected, green or bare ground wire.
Connect the appliance cable to the junction box through the CSA or UL-listed conduit
connector. Complete electrical connection according to local codes and ordinances.
CONNECT WITH COPPER WIRE ONLY
The flexible (4’) armoured cable should be connected directly to the junction box.
Do not cut the conduit.
A CSA or UL-listed conduit connector must be provided at the junction box.
Do not ground to a gas pipe.
Do not have a fuse in the grounding or neutral circuit.
Fuse both supply (phase) lines.
A time delay fuse or circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker box) through flexible,
armored or non-metallic shealted, copper cable (with grounding wire).
If codes permit and a separate grounding wire is used, it is recommended that a
qualified electrician determine that the grounding path and wire gauge is in
accordance with local codes.
If the appliance is to be completely enclosed in a cabinet, feed the appliance
cable through the opening in the cabinet. Make the electrical connection follow-
ing the appropriate steps for your installation.
1. Disconnect the power supply.
2. Remove the junction box cover.
3. Connect the appliance cable to the junction box through the CSA or UL-listed con-
duit connector.
4. Connect the two black wires together with twist-on connectors.
5. Connect the two red wires together with twist-on connectors.
6. Connect electrical connection according to local codes and ordinances.
If local codes PERMIT connecting cabinet-grounding conductor to neutral white
wire in the junction box:
7. Crimp the green & yellow (or green) and white oven wires.
8. Connect the crimped green & yellow (or green) and white oven cable wires to the
neutral (white) wire in the junction box (Fig. 6.1).
9. Replace the junction box cover.
OR If local codes DO NOT PERMIT connecting cabinet-grounding conductor to
neutral white wire in junction box:
7. Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).
8. Connect the green & yellow (or green) grounding appliance cable wire to a ground-
ed wire in the junction box.
9. Replace the junction box cover.
OR If connecting to a four-wire electrical system:
7. Connect white oven cable wire to neutral (white) wire in junction box (Fig. 6.2).
8. Connect the green & yellow (or green) appliance cable wire to the green & yellow (or
green) grounding wire in the junction box.
Do NOT connect the green & yellow (or green) appliance cable wire to neutral
(white) wire in junction box.
9. Replace the junction box cover.
electrical connection
TO AVOID ELECTRICAL SHOCK
HAZARD, BEFORE INSTALLING THE
APPLIANCE, SWITCH POWER OFF AT
THE SERVICE PANEL AND LOCK THE
PANEL TO PREVENT THE POWER
FROM BEING SWITCHED ON
ACCIDENTALLY.
WARNING
3-wire cable from
power supply
Black wires
Junction box
CSA or UL-listed
conduit connector
to appliance
Red wires
White
wires
Green & yellow
wire
(or green wire)
White wires
Junction box
CSA or UL-listed
conduit connector
to appliance
Red wires
Black wires
Green & yellow
wires
(or green wires)
4-wire cable from
power supply
Fig. 6.1
Fig. 6.2