DeLonghi DEGH90WF Cooktop User Manual


 
8
GAS SUPPLY:
The connection must be executed by an authorised person according to the relevant
standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor
onto the gas inlet pipe, upon which the gasket has been placed (figures 5a-5b).
Conical adaptor and gasket are supplied with the appliance (packed with conversion
kit for use with Natural gas or Universal LPG).
This appliance is suitable for use with Natural Gas or Universal LPG. (Check the “gas
type” sticker attached to the appliance).
For Natural Gas models the gas supply is connected to the pressure regulator which
is supplied with the appliance (fig. 5a). Adjust the regulator to obtain a test point
pressure of 1 kPa with the two semi-rapid (SR) burners operating at the maximum.
For Universal LPG models the gas supply is connected to the test point adaptor
which is supplied with the appliance (fig. 5b) and ensure that the supply pressure is
regulated to 2.75 kPa.
Do NOT force the ”elbow“ rotation prior to loosening nut.
Do NOT over tighten the nut at the ”elbow“.
Figure 5b
Figure 5a
Gas connection for
UNIVERSAL LPG
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas inlet pipe
Test
point
Gas connection for
NATURAL GAS
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point