DeLonghi DEGLSC 24 SS Range User Manual


 
9
3-Wire Flat Power Cord Installation
(See Figures 2.1 and 2.2)
1. Remove the Terminal Block Access Plate on the back of the
range by unscrewing the 4 fixing Screws.
2. Insert the Flat Power Cord through the Bracket; then tighten
the Flat Power Cord by using the Strain Relief. Allow
enough slack to easily attach the cord terminals to the
Terminal Block.
3. Remove the 3 wire terminal nuts and washers from the
Terminal Block.
4. Plug the terminal holes of Flat Power Cord. The Neutral or
Ground Wire of the Flat Power Cord must be connected to
the neutral terminal located in the center of Terminal Block.
The Power Wires must be connected to the outside termi-
nals.
5. Plug washers and tighten nuts securely.
Do not remove Ground strap.
6. Assemble the Terminal Block Access Plate.
Terminal Block
Access Plate
Screws
Neutral Wire
Power Wires
Bracket
Flat
Power Cord
Terminal Block
Ground strap
Strain Relief
Fig. 2.1
Fig. 2.2