12
MINIMUM BURNER SETTING ADJUSTMENT
Check whether the flame spreads to all burner ports when the burner is lit with the gas
tap set to the minimum position. If some ports do not light, increase the minimum gas
rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly from
the maximum to the minimum position. If the burner does not remain lit, increase the
minimum gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
■ Turn on the burner
■ Turn the tap to the MINIMUM position
■ Take off the knob
■ With a small flat screwdriver turn the screw “F” (fig. 9) to the correct regulation.
Normally for Propane gas, the regulation screw is tightened up.
Figure 9
F