Technical data
Mainsvoltage: 220-240V
˜
50/60Hz
Absorbedpower: 1000W
Weight:ICM15240/ICM15250 2.3kg
Disposing of the appliance
In compliancewith Europeandirective 2002/96/EC,
theappliancemustnotbedisposedofwithhousehold
waste,buttakentoanauthorisedwasteseparation
andrecyclingcentre.
TheappliancecomplieswiththefollowingECdirec-
tives:
• Low Voltage Directive 2006/95/EC and subsequent
amendments;
• EMCDirective2004/108/ECandsubsequentamendments
• ECRegulation1275/2008forstandby.
Troubleshooting
Problem Probable cause Solution
The coee takes longer to
brew.
Thecoeemakerneedstobedescaled. Descalethemachineasdescribedinthesection
DESCALING.
Thecoeehasanacidic
taste.
Insucientrinsingafterdescaling. Rinsethemachineasdescribedinthesection
DESCALING.
Electrical connection (UK only)
A) Ifyourappliancecomesttedwithaplug,itwillincorporatea13Ampfuse.Ifitdoesnottyoursocket,theplugshouldbecut
ofromthemainslead,andanappropriateplugtted,asbelow.
WARNING:Verycarefullydisposeofthecutoplugafterremovingthefuse:donotinsertina13Ampsocketelsewhereinthehouse
asthiscouldcauseashockhazard.Withalternativeplugsnotincorporatingafuse,thecircuitmustbeprotectedbya15Ampfuse.
Iftheplugisamoulded-ontype,thefusecovermustbere-ttedwhenchangingthefuseusinga13AmpAstaapprovedfuseto
BS1362.Intheeventoflosingthefusecover,theplugmustNOTbeuseduntilareplacementfusecovercanbeobtainedfromyour
nearestelectricaldealer.Thecolourofthecorrectreplacementfusecoveristhatasmarkedonthebaseoftheplug.
B) Ifyourapplianceisnotttedwithaplug,pleasefollowtheinstructinsprovidedbelow:
WARNING-THISAPPLIANCEMUSTBEEARTHED
IMPORTANT
Thewiresinthemainsleadarecolouredinaccordancewiththefollowingcode:
Greenandyellow: Earth
Blue: Neutral
Brown: Live
Asthecoloursofthewiresinthemainsleadmaynotcorrespondwiththecolouredmarkingsidentifyingtheterminalsinyourplug,
proceedasfollows:ThegreenandyellowwiremustbeconnectedtotheterminalintheplugmarkedwiththeletterEortheearth
symbol orcolouredgreenorgreenandyellow.ThebluewiremustbeconnectedtotheterminalmarkedwiththeletterNor
colouredblack.ThebrownwiremustbeconnectedtotheterminalmarkedwiththeletterLorcolouredred.