Delta Electronics AFB0612MD Ventilation Hood User Manual


 
13
60 x 60 x 20 MM SERIES
AFB
DIMENSIONS DRAWING
P & Q CURVE (AT RATED VOLTAGE)
MOUNTING PANEL CUTOUT
Bearing Type
Ball Bearings
Material
Impeller & Frame : Plastic (UL 94V-0)
Lead Wires :
UL 1007 AWG #24 OR Equivalent
Red Wire Positive (+)
Black Wire Negative (-)
Weight : 56g (1.98 oz)
*
*
*
*
* Function type is optional.
The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
Noise is measured in anechoic chamber in free air, one meter from intake side.
All readings are typical values at rated voltage.
Specifications are subject to change without notice.
*
*
*
*
LABEL
UNIT:
(INCH)
mm
mm
(INCH)
UNIT:
http://www.deltaww.com
*
Operating
Voltage
Range
MODEL
Rated
Voltage
Maximum
Air Flow
Speed
Maximum
Air Pressure
Noise
PART NO.
REV.
FUNCTION
VDC VDC
Amp
Watt
R.P.M
.
CFM
mmH
2
O
IN
H
2
O
dB-A
AFB0612VHD -A -R00 / -F00 12 7.0 to 13.8 0.19 2.28 5400 0.823 29.06 8.72 0.343 41.0
AFB0612SHD -A -R00 / -F00 12 7.0 to 13.8 0.28 3.36 6000 0.911 32.17 10.41 0.410 43.0
AFB0612EHD -A -R00 / -F00 12 7.0 to 13.8 0.31 3.72 6600 0.997 35.21 12.29 0.484 45.0
OUTLET SIDE
INLET SIDE
Input
Power
Input
Current