7. The battery is delivering sufficient power. If the power voltage is less than
10.4VDC, the unit will not operate. Check incoming voltage with multimeter by
putting the black lead on the negative terminal of the LOAD DUMP module and the
red lead on the positive terminal as shown. Unit must be running to check this
function.
8. If 12 volts are available to the unit as shown in step 7, check to see if the LOAD
DUMP module is defective. This module is used as a surge protector for the unit.
Removed the module from the unit and remove all wires. Wire the Danfoss module
as shown with the wires that were on the LOAD DUMP module.
LOAD DUMP
Module
DANFOSS
Module
LOAD DUMP