Dometic RM2800 Refrigerator User Manual


 
CLEARANCES
Minimum
clearances
in
inches
to combustible materials are
G. Top 0
K.
Side
0
L: Bottom 0
M: Rear 1
N: See example below
Clearance
M
between the
rearmost
part of the refrigerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the minimum
ventilation height
See Fig 11 and examples below
L
Fig.1 1
Refrigerator Overall product Installation product
Recess
Distance between
model
dimensions dimensions
dimensions top of condenser
and top of
Height
Width Depth
Height
Width
Depth
Height
Width
Depth
refrigerator
A
B
C
h
W
d
H
W
D
e
0
inch
30 3/8 21 11/16 22
1/16
20 1/4 20 3/8 29 3/4 20 1/2 21 3/8 1 1/4
RM2400inch
32 15/16 23 24 11/16 32 1/8 21 9/16 22 15/16 32 5/16 21 13/16 23 15/16 1 1/4
RM2500inch
40 13/16 23 24 11/16 40
21
9/16 22 15/16 40 3/16 21 13/16 23 15/16 1 1/4
RM26000
inch
52 23 24 11/16 51 3/16 21 9/16 22 15/16 51 3/8 21 13/16 23 15/16 1 1/8
RM28000
inch
57 15/16 24 15/16 24 11/16 57
1/8 23 7/16 22 15/16 57 1/2 23 13/166 23 15/16 1 1/8
This method of installation and these
clearences
will give you adequate space for servicing and proper installation.
d
e
T
h
EXAMPLES
The clearance N for the
RM
2300 model is derived at in the
following way.
Installation with upper and lower side vents
N= Minimum ventilation height 37 minus installation height
29 9/16 plus distance between condenser top and
refringera-
tor top 1 114
in:
N=37-29
9/16+1
1/4=8
11/16 inches
mm:
N=940-751+32=221
mm
Installation with roof vent and lower side vent
N=Minimum ventilation height 31 minus installation height
29 9116 plus distance between condenser top and refrigera-
tor top 1 114 plus distance between roof surface and
roof
vent
cap 5 114
in: N=31 -29 9/16+1 1/4+5 1/4=7 15/16 inches
mm:
N=787-751+32+134=202
mm
Fig.1 2
View from above