7
Electrical operation
1. 12V DC
The refrigerator should only be used while the motor is running.
1. Set energy selector switch (A) to.
The refrigerator operates without thermostatic
control (continuous operation).
2. Mains power
This option should only be selected where the supply voltage of the connection
for power supply corresponds to the value specified on the data plate.
Any difference in values may result in damage the appliance.
Gas operation
The refrigerator should only be operated using liquid gas
(propane, butane). Do not use town gas or natural gas.
If the refrigerator is operated during travel using gas, the precautions
stipulated by the legislation in the respective country must be taken (in
conformity with the European standard EN 732).
Operating the refrigerator with gas is not permitted during travel in
France and Australia.
As a basic rule, operation using gas is prohibited in petrol stations.
1. Open the valve of the gas cylinder
2. Open the shut-off valve to the gas supply.
Proceed to the description that applies to YOUR model.
1. Manual ignition
5.2.2
5.2.3
1. Set energy
selector switch (A)
to gas.
2. Press and hold
rotary switch.
4. Check the inspection glass to
see whether there is a flame
(the inspection glass is insi-
de the refrigerator at the
bottom left).
1. Set energy
selector switch
(A) to.
2. Use rotary
switch (B) to
regulate the
temperature in
the main refrige-
rator compart-
ment.
3. Activate Piezo
ignition (C)
several times at
intervals 1-2
seconds.
A
B
A
A
B
C