Dometic RM 7371 L Refrigerator User Manual


 
26
D+
connection and Solar Control connection
(
AES
only )
D+ connection
The D+ control connection must be connected to the respective vehicle
terminal (alternator signal while motor is running).
Solar control input (S+):
Connection only when using a solar system with a solar charging
controller with AES output.
The respective solar charging controllers are available from a specialized
dealer.
The “Solar” (S+) control connection must be connected to the respective
terminal of the solar charging controller (AES output).
Cable cross-sections
There are no particularly high current flows via the D+ and S+ connection;
therefore no particularly large cross-section is required for these connections
(approx. 1mm²).
Terminal strip
(RM 7XX1 L and RM 7XX5 L models
)
Retrofitting
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
D+ = alternator signal
S+ = AES-input-control signal
(solar charge regulator)
A B
D+
S+
C D
-
+
+
-
on the vehicle
on the appliance
6.9.3
6.9.4
6.9.5
For all RM 7xx1
MES
appliances there is an additional possibility for retrofit-
ting to an RM 7xx5 device with AES functions. Please consult your nearest