7
Electrical operation
1. 12V DC
The refrigerator should only be used while the motor is running.
Set energy selector switch (A) to 12 V .
The refrigerator operates without thermostatic
control (continuous operation).
2. Mains power
This option should only be selected where the supply voltage of the connection
for power supply corresponds to the value specified on the data plate. Any dif-
ference in values may result in damage the appliance.
Gas operation
5.2.2
5.2.3
All refrigerators, whether manual or automatic ignition, are equipped
with automatic flame protection, which automatically cuts off the sup-
ply of gas approximately 30 seconds after the flame goes out.
When using for the first time, and after changing the gas cylinder, the
gas pipes may contain air. By means of brief operation of the refrigera-
tor and any other gas appliances (e.g. cookers), air is removed from
the gas pipes. The gas will ignite without delay
The refrigerator should only be operated using liquid gas
(Propane, Butane). Do not use Autogas, town gas or natural gas.
If the refrigerator is operated during travel using gas, the precautions
stipulated by the legislation in the respective country must be taken (in
conformity with the European standard EN 732).
Due to physical reasons, ignition faults could occur starting from an
altitude above sea level of approx. 1000 m /3280 ft. (No malfunction!)
As a basic rule, operation using gas is prohibited in petrol stations.
A
1. Set energy
selector switch
(A) to
A
B
2. Use rotary switch
(B) to egulate the
temperature in
the main refrige-
rator compartment.