Dometic RM 7401 L Refrigerator User Manual


 
If gas faults occur the operating LED C
flashes
yellow.
Remedies:
Set the energy selector switch (A) to position OFF.
1. Is there any gas in the gas bottle?
2. Is the gas bottle valve open?
3. Is the on-board shut-off valve open?
4. Set the main switch (A) to on
The ignition starts again.
If after about 30 seconds the operating display (C) starts flashing red
again, the gas fault has not been cleared (e.g. air in the gas pipe).
5. Briefly switch the refrigerator off and then on again using main switch (A).
To remove air from the gas pipes, repeat this procedure 3-4 times.
If these actions do not help, please call an authorised Dometic Service Centre.
Additional functions
(RM 7XX5 L - models only)
Temperature setting cooling compartment
As shown, you are able to regulate the temperature of
the cooling compartment, if necessary, by turning
rotary knob (B) .
10
C
A
Gas faults at AUTO- mode
5.2.6
5.2.7
5.2.8
B
TTIIPP
medium setting
The cooling units performance is influenced by ambient temperatures.
Please select the medium setting for ambient temperatures between +15°C
and +25°C. The unit operates within its optimum performance range.
Underneath the fascia is a knurled knob
for adjusting the brightness
(see item E above)
E
D
E
l Temperature setting display (D) with 4 LED to
indicate the selected temperature (MIN - MAX)
l LED - dimmer (E) for adjusting the brightness of
the display-LED
(only accessible when door opens)